ASTM C1012 PDF

As researchers using ASTM C for sulfate resistance test for concrete. The size of the cube is x x mm. But ASTM C gives guidelines for. Table 1 Criticism of ASTM Sulfate Durability Tests (ASTM C and ASTM C) .. 8. Table 2 Designation, Classification, and Chemical Oxide Analysis of. C (ASTM a) Type II cement (moderate sulfate resistance) or Type V . chosen based on the ASTM C (ASTM b) specifications are shown in.

Author: Gotilar Fenrijin
Country: Serbia
Language: English (Spanish)
Genre: Automotive
Published (Last): 22 February 2016
Pages: 225
PDF File Size: 6.70 Mb
ePub File Size: 2.25 Mb
ISBN: 807-9-70731-686-3
Downloads: 63948
Price: Free* [*Free Regsitration Required]
Uploader: Doudal

The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Maintain the volume proportion of sulfate solution to mortar bars in a storage container at 4.

Work Item s – proposed revisions of this standard. Testing goes to 1 year. Method C is suitable for evaluating portland cements but not blended cements or blends of portland cement with pozzolans or slags.

The length change of mortar bars immersed in sulfate solution is the indicator. Link to Active This link will always route to the current Active version of the standard. Within the text, the inch-pound units are shown in brackets.

Print and complete the following order form. Enviado por Murilo flag Denunciar. Support the bars so that no end or side of a bar rests v1012 the container.

  ELECTRODYNAMICS BY SATYA PRAKASH PDF

Use This test provides astn means of assessing the sulfate resistance of a mortar. Further discussion of these and other technical issues is given in the Appendix. Instructions Supply 5 kg sample. Test Method C is suitable for evaluating portland cements but not blended cements or blends of portland cement with pozzolans or slags.

The values shown in parentheses are for information purposes only. Time for Results Please contact a CTLGroup chemical services representative or Project Manager to discuss your individual project needs and testing response times.

BoxFarmington Hills, MI Determine the pH of the solution before use; reject the solution if the pH range is outside 6.

ASTM C1012/C1012M – 18a

Last previous edition approved in as C — C — 04 Standard Test Method for Length Change of Hydraulic-Cement Mortars Exposed to a Sulfate Solution1 This standard is issued under the fixed designation C ; the number immediately following the designation indicates the year of original adoption or, in the case of revision, the year of last revision. Results Produced Length change of mortar bars immersed in sulfate solution. Significance and Use 3.

Combining values from the two systems may result in non-conformance with the standard. Use a water-cement ratio by mass of 0. Seal the container with a lid so that the sulfate solution cannot evaporate.

  ASTM D1401 PDF

For mortar bars 25 by 25 by mm volume mLthis is to mL of solution asttm mortar bar in the storage container.

ASTM C Hydraulic-Cement Mortars Exposed to a Sulfate | CTLGroup

Wstm you need more info or have any questions, please note the Lab ID number and contact us at: Such chemicals shall conform to the specifica- tions of the Committee on Analytical Reagents for the American Chemical Society where such specifications are available.

A number in parentheses indicates the year of last reapproval. Mix the solution on the day before use, cover, and store at Privacy Policy Sensors Sitemap. It is the responsibility of the user of this standard to establish appro- priate safety and health practices and determine the applica- bility of regulatory limitations prior to use.

When tests are astn that are expected to produce results that are close to an acceptance- rejection value, it is recommended that reagent grade chemi- d1012 be used. Current edition approved Jan.